Diathermy Electrosurgical Unit SURTRON 400HP Watt-دياثرمي 400 وات

EGP125,000.00

SURTRON 400 HP Can Be Used To Simultaneously Perform Monopolar And Bipolar Surgery In Application Fields Which Require High Precision And Reliability.

2 MONOPOLAR AND BIPOLAR
VESSEL SEALING UP TO 7mm
AUTO START/STOP IN BIPOLAR COAG

APPLICATIONS: AMBULATORY SURGERY- ENDOSCOPY- FIRST AID -GASTROENTEROLOGY- GENERAL SURGERY- GYNECOLOGY – NEUROSURGERY- OTORHINOLARYNGOLOGY- ORTHOPEDICS- PEDIATRIC SURGERY- PLASTIC SURGERY- PNEUMOLOGY- UROLOGY- VASCULAR SURGERY -VETERINARY

DOUBLE ACTIVITY ‘OPERATION
• Two Output Channels For Monopolar Cutting
• Two Independent Setting And Output Channels For Monopolar Coagulation More Frequently

CONTROLLED CUTTING PROCEDURES
• Cutting Currents For Eschar Free Incision
• Cutting Current With Selectable Coagulating Property For Bleeding-Controlled Dissection
• Low Capacitive Coupling By Current Endoscopic Procedures Slow BLEND

DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * And Two Operators
• SPRAY COAG Achievable With Handpiece Or Pedal

WIDE BIPOLAR FEATURES
• Bipolar Cutting With Bleeding Control
• Cutting Current Slow BLEND
• Start And Stop Automatic Activated Separately

TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability Of Contact Impedance Between The Patient’s Body And The Neutral Plate Constantly Verified By The Electronic Control Skin Plate Electronic Control Called SPEC
• Continuous Monitoring Of Leakage Current
• Change In Automatically Compensated Mains Voltage Before Starting The RF Power Output

CUSTOM PROCEDURES
• Independent Choice Of Coagulation Currents And Power Levels Of Each Of The Two Operators
• Ten Configurable Personal Procedures And Immediately Recallable

CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• Outputs For Connections Driven Argon Plasma Units And Smoke Aspirator

AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP
• Automatic Diagnostic Control Of The Actual Complete Electronic Drive Functionality And Accessories Connected And Coded Report Of Found Failures

Coag SPEEDY Is Also Called Fulgurate Or Forced
Coag DEEP Is Also Called Pin Point, Dessicate Or Soft

FEATURES

Max Output Power Monopolar Pure CUT 400 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT80% 300 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT60% 250 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT40% 200 W – 300 Ω
Max Output Power Monopolar Cut ENHANCED 250 W – 500 Ω
Max Output Power Monopolar Cut-Coag BLEND 250 W – 300 Ω
Max Output Power Monopolar Coag SPEEDY 120 W – 500 Ω
Max Output Power Monopolar Coag DEEP 120 W – 200 Ω
Max Output Power Monopolar Coag SPRAY 120 W – 2000 Ω
Max Output Power Monopolar Coag SPRAY ARGON 120 W – 2000 Ω
Max Output Power Bipolar CUT 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT80% 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT60% 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT40% 100 W – 50 Ω
Max Output Power Bipolar Cut-Coag BLEND 120 W – 150 Ω
Max Output Power Bipolar Coag COAG 120 W – 50 Ω
Vessel Sealing 200 W – 50 Ω
Working Frequency Monopolar / Bipolar 425 KHz / 525 KHz
Patient Circuit F
Selectable Input Voltage 115 – 230 Vac
Mains Frequency 50 – 60 Hz
Electrical Input Power 1000 VA
Size WxHxD 470x150x400 Mm
Weight 17,5 Kgs
CONTROLS:

Patient/Plate Circuit Monitoring
Output Power Monitoring
Self Check Control
H.F. Leakage Currents Control
Compensation Of Mains Fluctuation
SAFETY:

EN60601-1
EN60601-1-2
EN60601-2-2
Level Of Protection Provided By Housing: IP21
Electrical Classification: CF
MDD 93/42 / EC: II B
STANDARD ACCESSORIES:

Disposable Handle With Switches (5pcs)
Reusable Handle With Switches
Blade Electrode 7 Cm (3 Pcs)
Blade Electrode 16 Cm (3 Pcs)
Needle Electrode 7 Cm (3 Pcs)
Ball Electrode 6 Cm (3 Pcs)
Cable For Neutral Electrode
Disposable Split Neutral Electrode (5pcs)
Double Water-Proof Foot-Switch (2 Pcs)
Power Supply Cable 5 Mt

التصنيف:

الوصف

Diathermy Electrosurgical Unit SURTRON 400HP Watt-دياثرمي 400 وات
Used To Simultaneously Perform Monopolar And Bipolar Surgery In Application Fields Which Require High Precision And Reliability.

SURTRON 400 HP Can Be Used To Simultaneously Perform Monopolar And Bipolar Surgery In Application Fields Which Require High Precision And Reliability.

2 MONOPOLAR AND BIPOLAR
VESSEL SEALING UP TO 7mm
AUTO START/STOP IN BIPOLAR COAG

APPLICATIONS: AMBULATORY SURGERY- ENDOSCOPY- FIRST AID -GASTROENTEROLOGY- GENERAL SURGERY- GYNECOLOGY – NEUROSURGERY- OTORHINOLARYNGOLOGY- ORTHOPEDICS- PEDIATRIC SURGERY- PLASTIC SURGERY- PNEUMOLOGY- UROLOGY- VASCULAR SURGERY -VETERINARY

DOUBLE ACTIVITY ‘OPERATION
• Two Output Channels For Monopolar Cutting
• Two Independent Setting And Output Channels For Monopolar Coagulation More Frequently

CONTROLLED CUTTING PROCEDURES
• Cutting Currents For Eschar Free Incision
• Cutting Current With Selectable Coagulating Property For Bleeding-Controlled Dissection
• Low Capacitive Coupling By Current Endoscopic Procedures Slow BLEND

DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * And Two Operators
• SPRAY COAG Achievable With Handpiece Or Pedal

WIDE BIPOLAR FEATURES
• Bipolar Cutting With Bleeding Control
• Cutting Current Slow BLEND
• Start And Stop Automatic Activated Separately

TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability Of Contact Impedance Between The Patient’s Body And The Neutral Plate Constantly Verified By The Electronic Control Skin Plate Electronic Control Called SPEC
• Continuous Monitoring Of Leakage Current
• Change In Automatically Compensated Mains Voltage Before Starting The RF Power Output

CUSTOM PROCEDURES
• Independent Choice Of Coagulation Currents And Power Levels Of Each Of The Two Operators
• Ten Configurable Personal Procedures And Immediately Recallable

CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• Outputs For Connections Driven Argon Plasma Units And Smoke Aspirator

AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP
• Automatic Diagnostic Control Of The Actual Complete Electronic Drive Functionality And Accessories Connected And Coded Report Of Found Failures

Coag SPEEDY Is Also Called Fulgurate Or Forced
Coag DEEP Is Also Called Pin Point, Dessicate Or Soft

FEATURES

Max Output Power Monopolar Pure CUT 400 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT80% 300 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT60% 250 W – 300 Ω
Max Output Power Monopolar Cut-Coag CUT40% 200 W – 300 Ω
Max Output Power Monopolar Cut ENHANCED 250 W – 500 Ω
Max Output Power Monopolar Cut-Coag BLEND 250 W – 300 Ω
Max Output Power Monopolar Coag SPEEDY 120 W – 500 Ω
Max Output Power Monopolar Coag DEEP 120 W – 200 Ω
Max Output Power Monopolar Coag SPRAY 120 W – 2000 Ω
Max Output Power Monopolar Coag SPRAY ARGON 120 W – 2000 Ω
Max Output Power Bipolar CUT 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT80% 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT60% 120 W – 50 Ω
Max Output Power Bipolar Cut-Coag CUT40% 100 W – 50 Ω
Max Output Power Bipolar Cut-Coag BLEND 120 W – 150 Ω
Max Output Power Bipolar Coag COAG 120 W – 50 Ω
Vessel Sealing 200 W – 50 Ω
Working Frequency Monopolar / Bipolar 425 KHz / 525 KHz
Patient Circuit F
Selectable Input Voltage 115 – 230 Vac
Mains Frequency 50 – 60 Hz
Electrical Input Power 1000 VA
Size WxHxD 470x150x400 Mm
Weight 17,5 Kgs
CONTROLS:

Patient/Plate Circuit Monitoring
Output Power Monitoring
Self Check Control
H.F. Leakage Currents Control
Compensation Of Mains Fluctuation
SAFETY:

EN60601-1
EN60601-1-2
EN60601-2-2
Level Of Protection Provided By Housing: IP21
Electrical Classification: CF
MDD 93/42 / EC: II B
STANDARD ACCESSORIES:

Disposable Handle With Switches (5pcs)
Reusable Handle With Switches
Blade Electrode 7 Cm (3 Pcs)
Blade Electrode 16 Cm (3 Pcs)
Needle Electrode 7 Cm (3 Pcs)
Ball Electrode 6 Cm (3 Pcs)
Cable For Neutral Electrode
Disposable Split Neutral Electrode (5pcs)
Double Water-Proof Foot-Switch (2 Pcs)
Power Supply Cable 5 Mt