Single Channel Syringe Pump Is A The Most Common See And Popular Iv Syringe Driver Pump Among All Models
Categories: Intensive Care Units, Syringe & Infusion Pump
Brand: SINO MDT
Specifications

Single Channel Syringe Pump Is A The Most Common See And Popular Iv Syringe Driver Pump Among All Models.
It Features Stable Quality, Easy To Operate, And Automatic Calibration And Most Importantly Accurate Injection.
Various Modes Support Includes Time Mode, Speed Mode, Body Weight Mode And Drug Library Mode.
FEATURES

Calibrating Syringe Automatically
Identifying Syringe Size Automatically
3-Level Occlusion Alarm Limits Setting
Automatically Reducing Impacts Does Release After Occlusion
Limits Setting
Delivered Volume Inquiry
KVO Flow Rate (0.1-1.0 Ml/H Adjustable)
Fast Rate Control
“Purge” Button Activates Safe Projection
Flow Rate Setting Button Lock
Abundant Optic And Sound Alarm
Ac And Internal Power Indications
Standard Rs232 Interface
1000 History Of Records
Multi-Direction Clamp For Either Horizontal Or Vertical Fixation
PRODUCT SP Technical ECIFICATIONS

SYRINGE 10,20,30,50 ML Of Calibration Syringe
FLOW RATE 0.1-1500mL/H
0.1-900mL/H

0.1-600mL/H

0.1-400mL/H

PURGE RATE 1500mL/H 50mL Syringe
900mL/H 30 ML Syringe

600mL/H 20mL Syringe

400mL/H 10mL Syringe

ACCURACY OF FLOW RATE
(NOMINAL VALUE)

Accuracy Including Syringe: Within ±2%
Mechanical Accuracy: Within ±1%

DISPLAY RANGE OF VOLUME DELIVERED 0.1-9999 ML
SETTING OF DELIVERY LIMIT 0.1-9999 ML
OCCLUSION DETECTION PRESSURE H: 800 ±200 MmHg
C: 500 ±100 MmHg

L: 300 ±100 MmHg

ALARMS Occlusion
Near Empty

Finish

Syringe Dislocated

Plunger/Clutch Disengaged

Battery Low

Battery Exhausted

Power Cable Disconnected

Flow Rate Over Limit

Volume Over Limit

Non-Operation Time Over

POWER
AC 110-220v ±10%,50/60 Hz ±Hz

Inner NiMH Battery: DC 12 V

Continuous Operation Time Battery: Over 6 Hours For One Channel When The Battery Is Recharged For 12 Hours, At Flow Rate Of 5 ML/H

OPERATION CONDITIONS Ambient Temperature: 5 To 40’C
Relative Humidity:20-50’C

STORAGE CONDITIONS Ambient Temperature: -20 To 50’C
Relative Humidity:<95%

ELECTRIC SHOCK PROTECTION Class 1 And Internal Power Supply: Type CF, Continous Operation
WATERPROOF LEVEL IPX4
WEIGHT 2.25kg (With Clamp Base)
DIMENSION 306mm (W)X135mm (H)X127mm(D)

التصنيف:

الوصف

Syringe Pump SN-50C6-سرنجة محاليل
POA
Single Channel Syringe Pump Is A The Most Common See And Popular Iv Syringe Driver Pump Among All Models
Categories: Intensive Care Units, Syringe & Infusion Pump
Brand: SINO MDT
Specifications

Single Channel Syringe Pump Is A The Most Common See And Popular Iv Syringe Driver Pump Among All Models.
It Features Stable Quality, Easy To Operate, And Automatic Calibration And Most Importantly Accurate Injection.
Various Modes Support Includes Time Mode, Speed Mode, Body Weight Mode And Drug Library Mode.
FEATURES

Calibrating Syringe Automatically
Identifying Syringe Size Automatically
3-Level Occlusion Alarm Limits Setting
Automatically Reducing Impacts Does Release After Occlusion
Limits Setting
Delivered Volume Inquiry
KVO Flow Rate (0.1-1.0 Ml/H Adjustable)
Fast Rate Control
“Purge” Button Activates Safe Projection
Flow Rate Setting Button Lock
Abundant Optic And Sound Alarm
Ac And Internal Power Indications
Standard Rs232 Interface
1000 History Of Records
Multi-Direction Clamp For Either Horizontal Or Vertical Fixation
PRODUCT SP Technical ECIFICATIONS

SYRINGE 10,20,30,50 ML Of Calibration Syringe
FLOW RATE 0.1-1500mL/H
0.1-900mL/H

0.1-600mL/H

0.1-400mL/H

PURGE RATE 1500mL/H 50mL Syringe
900mL/H 30 ML Syringe

600mL/H 20mL Syringe

400mL/H 10mL Syringe

ACCURACY OF FLOW RATE
(NOMINAL VALUE)

Accuracy Including Syringe: Within ±2%
Mechanical Accuracy: Within ±1%

DISPLAY RANGE OF VOLUME DELIVERED 0.1-9999 ML
SETTING OF DELIVERY LIMIT 0.1-9999 ML
OCCLUSION DETECTION PRESSURE H: 800 ±200 MmHg
C: 500 ±100 MmHg

L: 300 ±100 MmHg

ALARMS Occlusion
Near Empty

Finish

Syringe Dislocated

Plunger/Clutch Disengaged

Battery Low

Battery Exhausted

Power Cable Disconnected

Flow Rate Over Limit

Volume Over Limit

Non-Operation Time Over

POWER
AC 110-220v ±10%,50/60 Hz ±Hz

Inner NiMH Battery: DC 12 V

Continuous Operation Time Battery: Over 6 Hours For One Channel When The Battery Is Recharged For 12 Hours, At Flow Rate Of 5 ML/H

OPERATION CONDITIONS Ambient Temperature: 5 To 40’C
Relative Humidity:20-50’C

STORAGE CONDITIONS Ambient Temperature: -20 To 50’C
Relative Humidity:<95%

ELECTRIC SHOCK PROTECTION Class 1 And Internal Power Supply: Type CF, Continous Operation
WATERPROOF LEVEL IPX4
WEIGHT 2.25kg (With Clamp Base)