Apneumatically Driven Time-Cycled Ventilator With Preset Volume And Flow Rate For Adult Or Pediatric Patients.
Specifications
»The Nuffield 200 Ventilator Has An Enviable Reputation As A Reliable Compact, Powerful And Easy To Use Anesthesia Ventilator And Is Primarily For Use With A Bain Co-Axial Circuit.
»The Ventilator Is Equally Suitable For Use With An Ayre’s Tee Circuit For Resuscitation, For High-Frequency Positive Pressure Ventilation With The Use Of A Bronchoscope Injector, And In A Closed-Circuit System Incorporating A CO2 Absorber.
»The Time-Cycled Penlon Nuffield 200 Is Powered By Medical Air Or Oxygen At 340 KPa- 410 KPa And Has Pre-Set Volume And Flow Rate For Small And Large Animals. You Can Replace The Standard Patient Valve With A Newton Valve And The Ventilator Range Is Further Extended To Include Ventilation Of Small Animals — A Considerable Achievement For A Small, Inexpensive Ventilator. A Considerable Achievement For A Small, Inexpensive Ventilator.
»The Nuffield 200 Is A Pneumatically Driven Time-Cycled Ventilator With Preset Volume And Flow Rate For Adult Or Pediatric Patients. The Four Simple Controls Provide A Wide Range Of Settings That Enable A Constant Flow During The Inspiratory Phase And Infinite Variability Of I: E Settings. A Suitable Ventilator Alarm And Pollution Control System Can Be Attached To The Ventilator If Required.
»The Penlon Series 200 Requires A Higher Drive Pressure To Work. It Will Not Work With An O2 Concentrator Due To Their Low-Pressure Output.
Compact, Easy To Use
Multi-Use Capabilities, Including Co-Axial Circuit, Ayre’s Tee Circuit, Circle System And Resuscitation
Comes With Adult & Pediatric Valve
Standard Schrader Probe Oxygen Hose Fitting
MRI Compatible (Optional)
Main Unit And Valves Can Be Sold Separately – Please Ask
Technical Specifications
Dimensions 270 X 210 X 100 Mm
Weight 3.5 Kg
Drive Gas Medical Air Or Oxygen At 340 KPa (50 Lbf/In 2) – 410 KPa (60 Lbf/In2)
Tidal Volume 10 Ml – 300 Ml (Newton Valve) » 50 Ml – 2000 Ml (Standard Valve)
Frequency (Cycle/Min) 10 – 85 (Cycle/Min)
Frequency For HFPPV 60 – 125 (Cycle/Min)
Inspiratory Flow (Liters Per Sec) 0.25 – 1.0 (Independent And Continuously Variable)
I: E Ratio: Continuously Variable And Dependent On Chosen I E Settings
Gas Consumption Minute Volume Plus 0.1 Liter/Cycle To Power Fluid Logic Circuit
Minute Volume 1.0 – 30.0 Liters
Inspiratory Time: 0.2 – 2.0 Sec. (Independent And Continuously Variable) » Flow: 0.25 – 1.0 Liters/Sec (Independent And Continuously Variable) » Pressure Relief: 60 CmH2O
Expiratory Time: 0.5 – 4.0 Sec. (Independent And Continuously Variable) » Resistance: 2.5 Cm H2O/Liter
Respiratory Manometer Range -20 To +100 CmH 2O With Zero Adjust Facility