الوصف
The Dexxum T Bone Densitometer By OsteoSys Provides Diagnostic Measurement By “Gold-Standard” At Both Femur And Spine, With Folding – Down Sides And Axial DEXA Measurement Method.
Categories: Bone Density X-Ray, Diagnostic & Imaging, Radiology Imaging, X-Ray Machines
Brand: OsteoSys
Specifications
The Dexxum T Bone Densitometer By OsteoSys Provides Diagnostic Measurement By “Gold-Standard” At Both Femur And Spine, With Folding – Down Sides And Axial DEXA Measurement Method.
Its Main Characteristics Are:
Bone Mineral Density Measured On Spine, Femur And Forearm
Very Good Reproducibility Through High Precision
Automatic Determination Of ROI (Region Of Interest)
Laser – Controlled Positioning
Intuitive Is Through User – Friendly Software
Extensive Reporting And Archiving
Space – Saving
Including PC, PC-Desk, And Printer
Technical Data:
System DEXA (Dual Energy X-Ray Absorptiometry)
Scan-Method Pencil Beam
Scan – Area Spine, Femur, Forearm
Scan – Time Spine: 3 Min / Femur: 2 Min
Precision <1%
Calibration Daily Automatic Calibration With Phantom
Positioning Through Laser
Image Transmission DICOM
Dimensions Max. 2.000 X 800 X 1.221 Mm
Compact 1.255 X 800 X 1.211 Mm
Weight Ca. 130kg
Key Features Of DEXXUM
PENCIL BEAM DEXA-Based CENTRAL DEXA Bone Mineral Densitometer
Wider Range Of Clinical Tests By Measuring AP SPINE And FEMUR
The Widest Scanning Scope Among Peers (950mm*550mm)/Fast Testing Function
Adopted Design Concepts Of Nude Type, Compact, Sophisticated And Ergonomic, Looking Elegant And High-End In Any Circumstances
Strengths Of The Tester
Automatic Soft Tissue Calibration And Boundary Distinction
DICOM System Support
Scanning Method Pencil Beam
Measuring Area And Time AP Spine (1 Min. 25 Sec.), Femur (1 Min. 5 Sec.) In Fast Mode
Measuring Method Non-Stop Scan (AP Spine, Dual Femur), Possible To Simultaneously Measure 3 Different Spots
Excellent Repeatability Below 1% Of Precision & Accuracy
Point Edit Users Can Add Or Delete Bones Or Tissues To Minimize Errors In BMD Computation Due To Medical Treatment History Incl. Fracture, Implant Or Operation
Auto ROI Automatic ROI Distinction After Completion Of Measurement
Micro Emission Of X-Ray No Need For Radiation Blocking Room
Use-Friendly Operation Easy To Register Patients And Measure BMD
Multiple Printout Measurement Date, Analysis Date, Average Abdominal Thickness Of Patients
Auto Tube Current Adjustment (Calibration) For Slim Patients Through Auto Tube Current Depending On Height And Weight Of Patients
Data Comparison Comparison Of Trend Data For Each Body Spot
Cross-Shaped Laser Point Minimize Operator’s Errors
DEXXUM Specification
X-Ray System DEXA (Dual Energy X-Ray Absorptiometry)
Scan Method Pencil Beam
Scan Site AP Spine, Femur, Dual Femur
Scan Time (Fast) AP Spine: 1 Min. 25 Sec. Femur: 1 Min. 5 Sec.
(Normal) AP Spine: 3 Min. 07 Sec. Femur: 2 Min.
Measurement Parameter BMD, BMC, Area, Tissue Thickness
Calibration System Automatic Calibration, Calibration Phantom
Precision & Accuracy < 1%
Patient Positioning Laser Aid Positioning
Image Transmission DICOM System
Operating System Windows XP, 2000 And Vista
Monitor LCD Monitor (1280 * 1024 Pixel)
Printer Color Ink Jet With 300*300 Dpi Resolution
Dimension 2083 * 1066 * 1230 Mm
Weight 132.5 Kg