Infusion Pump SK 600I V2-مضخة محاليل

EGP0.00

Infusion Pump Is Compatible With Most Of The Current Silicone IV Sets. This Compact Device Works Both On Battery And Mains Supply And Is Perfectly Adapted For Patients Use.Categories: Intensive Care Units, Syringe & Infusion Pump
Brand: Sk
Applications:

– During Surgery

– In Reanimation

– On Dehydrated Patients

Flow And Performance:

Flow From 0.1 To 1 500 Ml/H
VTBI 0.1 To 999.9 Ml/H, Increment Is 0.1 Ml/H, 1 000 To 9 999 Ml/H, Increment Is 1 Ml/H
Accumulated Volume 1 – 9999ml
Accuracy: ± 5% • KVO Rate 0.5 Ml/H
Bolus Rate From 0,10 To 1 500 Ml/H
Occlusion · Low: 150 ± 125 MmHg
· Medium: 525 ± 125 MmHg

· High: 900 ± 180 MmHg

Air Bubble Detection · Single Bubble Detection: 50, 100, 250, 500 And 800 Μl
· Accumulated Bubble Detection: From 0.1 To 4.0 Ml/H

Display:

Flow Rate
Programmed Volume
Accumulated Infusion Volume
Battery Load Indicator
Over (Infusion Completed)
Technical Data:

Flow 1 500ml/H
Accumulated Volume 1 – 9999 Ml
Accuracy ± 5%
Alarm Volume 8 Levels
Dimensions 146 X 193 X 95 Mm
Weight 1.6 Kg
Power 100-240V, 50/60 HZ
Battery Lithium Battery Operation Time: > 4 Hours @ 25 Ml/H
Charging Time ≥ 6 Hours
Data Interface RS232
Alarm:

VTBI Done, VTBI Near Done, VTBI Finish
Bottle Empty
Door Open
Occlusion
Air In Line
System Error, System Abnormal
Battery Low, Battery Empty
Reminder
AC Power Disconnection
Ergonomy:

2.5 LCD Screen
Embedded Handle For Easy Transportation
Anti-Free Flow Clamp
Application Fields

Intensive Care
A Continuous Infusion Is Vital To Any Dehydrated Patient.

The Flow Rate Is Conditioned By The Required Volume And The Duration Of The Infusion:

Volume To Infuse = Initial Deficit To Compensate (1) + Maintenance Need (2) + Loss (3)

Deficit To Compensate In Liter = Weight (Kg) X % Of Dehydration / 100
During Surgery:

Low Blood Loss 10 Ml/Kg/H / With
Normal Blood Loss 15 Ml/Kg/H
High Blood Loss 20 Ml/Kg/H
Infusion Liquid Lactated Ringer’s Solution
Post-Operatory Care Until Discharge 2 Ml/Kg/H
Infusion Liquid 1/3 Of Isotonic Sodium Chloride Solution, 2/3 Of Isotonic Glucose Solution
Long-Term Infusion:

Long-Term Infusions Show Much Better Results Than Other Ways Of Administration.
Accuracy:

By Means Of An IV Pump The Animal Can Be Supplied With Exactly The Necessary Volume Of Medication Or Liquid According To Its Size And Needs.
SK 600I V2 Beneficial:

SK 600I V2 Infusion Pump Can Be Used With Most Of The Current IV Sets. The Investment Gives An Excellent Return. Moreover, An Infusion Pump Is Comfortable And Safe Both For You And Your Client And Ensures Advanced Care Efficiency.

التصنيف:

الوصف

Infusion Pump Is Compatible With Most Of The Current Silicone IV Sets. This Compact Device Works Both On Battery And Mains Supply And Is Perfectly Adapted For Patients Use.Categories: Intensive Care Units, Syringe & Infusion Pump
Brand: Sk
Applications:

– During Surgery

– In Reanimation

– On Dehydrated Patients

Flow And Performance:

Flow From 0.1 To 1 500 Ml/H
VTBI 0.1 To 999.9 Ml/H, Increment Is 0.1 Ml/H, 1 000 To 9 999 Ml/H, Increment Is 1 Ml/H
Accumulated Volume 1 – 9999ml
Accuracy: ± 5% • KVO Rate 0.5 Ml/H
Bolus Rate From 0,10 To 1 500 Ml/H
Occlusion · Low: 150 ± 125 MmHg
· Medium: 525 ± 125 MmHg

· High: 900 ± 180 MmHg

Air Bubble Detection · Single Bubble Detection: 50, 100, 250, 500 And 800 Μl
· Accumulated Bubble Detection: From 0.1 To 4.0 Ml/H

Display:

Flow Rate
Programmed Volume
Accumulated Infusion Volume
Battery Load Indicator
Over (Infusion Completed)
Technical Data:

Flow 1 500ml/H
Accumulated Volume 1 – 9999 Ml
Accuracy ± 5%
Alarm Volume 8 Levels
Dimensions 146 X 193 X 95 Mm
Weight 1.6 Kg
Power 100-240V, 50/60 HZ
Battery Lithium Battery Operation Time: > 4 Hours @ 25 Ml/H
Charging Time ≥ 6 Hours
Data Interface RS232
Alarm:

VTBI Done, VTBI Near Done, VTBI Finish
Bottle Empty
Door Open
Occlusion
Air In Line
System Error, System Abnormal
Battery Low, Battery Empty
Reminder
AC Power Disconnection
Ergonomy:

2.5 LCD Screen
Embedded Handle For Easy Transportation
Anti-Free Flow Clamp
Application Fields

Intensive Care
A Continuous Infusion Is Vital To Any Dehydrated Patient.

The Flow Rate Is Conditioned By The Required Volume And The Duration Of The Infusion:

Volume To Infuse = Initial Deficit To Compensate (1) + Maintenance Need (2) + Loss (3)

Deficit To Compensate In Liter = Weight (Kg) X % Of Dehydration / 100
During Surgery:

Low Blood Loss 10 Ml/Kg/H / With
Normal Blood Loss 15 Ml/Kg/H
High Blood Loss 20 Ml/Kg/H
Infusion Liquid Lactated Ringer’s Solution
Post-Operatory Care Until Discharge 2 Ml/Kg/H
Infusion Liquid 1/3 Of Isotonic Sodium Chloride Solution, 2/3 Of Isotonic Glucose Solution
Long-Term Infusion:

Long-Term Infusions Show Much Better Results Than Other Ways Of Administration.
Accuracy:

By Means Of An IV Pump The Animal Can Be Supplied With Exactly The Necessary Volume Of Medication Or Liquid According To Its Size And Needs.
SK 600I V2 Beneficial:

SK 600I V2 Infusion Pump Can Be Used With Most Of The Current IV Sets. The Investment Gives An Excellent Return. Moreover, An Infusion Pump Is Comfortable And Safe Both For You And Your Client And Ensures Advanced Care Efficiency.